Set up the legs of the tripod so that they are firmly secured
and the and the plate is approximately horizontal.
Take
the level out of the box, and while still holding firmly, attach
it to the head of the legs using the plate nut.
Centralise
the circular bubble using the footscrews on the tribrach of the
level.
Eliminate
parallax - This will occur when the crosshairs are not brought
into sharp focus. Parallax is present when the crosshairs appear
to move when the position of your eye changes. To eliminate parallax
it is necessary to bring the cross hairs into sharp focus using
the eyepiece focusing screw.
Centre the vertical cross-hair on the levelling staff and clamp
the telescope.
Focus onto the staff.
With the staff in the field of view as shown above, record the
staff reading as shown by the horizontal cross-hair.